Packaged Low Temperature Chillers


CLM Series: -10ºF to -60ºF LCT

The CLM Series provides a packaged low temperature chiller solution to your process needs. This fully packaged system includes a robust and high efficiency refrigeration circuit, which includes semi-hermetic single or compound reciprocating compressors. Modules are connected, to increase cooling capacity and complete a chiller system. Structured equipment enclosure, integrated reservoir tank, primary and secondary pumps and component/system protection are standard features of this packaged chiller.

Air cooled and water cooled (pictured) modules are designed with accessibility in mind yet remain space efficient for an overall smaller footprint.

This particular module is part of a packaged low temperature chiller system:

 
Major Features of the CLM Series:
Packaged air or water cooled chiller designed to ideally match your requirements
Industrial two-stage compound compressor
Extreme duty stainless steel fan shroud (on air cooled models)
Breakers and motor protects - No Fuses
Large stainless steel reservoir tank with system and bypass pump assembly
Indoor/Outdoor operation
Ventilated Control Cabinet
 
Brochure
 
Process Chiller Options:
Mounted Casters
Super Low Ambient Kit
High Ambient/ Altitude Operation
Stainless Steel Panels and Hardware
Heresite Coated Condenser Coils
Disconnect Switch
VPM Voltage Phase Monitor
40 PSI Pump @ rated GPM
50 PSI Pump @ rated GPM
60 PSI Pump @ rated GPM
70 PSI Pump @ rated GPM
 
80 PSI Pump @ Rated GPM
90 PSI Pump @ Rated GPM
100 PSI Pump @ Rated GPM
Tank Auto-Fill
Tank Level Alarm/ Switch
Tank Fill Pressure Reducing Valve
System Pump VFD
System Pump Pressure Gauge
Flow Switch (paddle)
Vibration Isolation Floor Mounts
Remote Operating/Monitoring Panel
 
Low Temperature Air Cooled Process Chillers
Model Physical
Dimensions
Unit MCA (460/3/60) Capacity @ 95ºF Ambient
(1,000’s BTUH)
Supply/ Return
Pipe Size
Condenser CFM Shipping Weight
-10ºF LCT -25ºF LCT -40ºF LCT
CLM-5-A
56”L x 32” W x 62”H
20
31
22
16
1-1/2"
5,200
900 lbs.
CLM-8-A
56”L x 32” W x 62”H
40
43
32
22
1-1/2"
8,000
1,000 lbs.
CLM-12-A
64”L x 39” W x 72”H
60
66
50
36
2"
12,000
1,350 lbs.
CLM-16-A
64”L x 39” W x 76”H
60
93
71
52
2"
20,000
1,550 lbs.
CLM-20-A
64”L x 39” W x 76”H
80
107
81
60
3"
28,000
1,650 lbs.
CLM-25-A
72”L x 72”W x 80”H
100
122
93
68
3"
40,000
3,250 lbs.
CLM-30-A
96”L x 72”W x 80”H
110
144
110
81
3"
48,000
3,450 lbs.
 
Low Temperature Water Cooled Process Chiller
Model Physical
Dimensions
Unit MCA (460/3/60) Capacity@ 85ºF Water Temp
(1,000’s BTUH)
Supply/ Return
Pipe Size
Condenser Water
Pipe Size
Shipping Weight
-10ºF LCT -25ºF LCT -40ºF LCT
56”L x 32” W x 62”H
20
32
23
17
1-1/2"
1"
900 lbs.
CLM-8-W
56”L x 32” W x 62”H
30
46
33
24
1-1/2"
1-1/4"
1,000 lbs.
CLM-12-W
64”L x 39” W x 72”H
50
70
53
38
2"
2"
1,350 lbs.
CLM-16-W
64”L x 39” W x 76”H
60
99
75
55
2"
2-1/2"
1,550 lbs.
CLM-20-W
64”L x 39” W x 76”H
80
114
87
63
3"
2-1/2"
1,650 lbs.
CLM-25-W
72”L x 72”W x 80”H
90
130
99
72
3"
2-1/2"
3,250 lbs.
CLM-30-W
96”L x 72”W x 80”H
110
154
118
86
3"
2-1/2"
3,450 lbs.
 
*Water Cooled units require 2 GPM per ton condenser water flow.
 
 
General Description

The CLM series packaged fluid chillers are designed for applications from -10°F to -60°F leaving coolant temperatures. Air cooled models have condensers situated atop the equipment enclosure and are constructed with corrosion resistant materials. Water cooled modules use space efficiently by securing the compressor above the heat exchanger assembly. The chiller package includes multiple independent compressor/refrigeration circuits, an insulated stainless steel reservoir tank with interior thermal baffle, system pump, an independent condenser section per compressor circuit, and all operating and safety controls. Available as an option, the chiller can be packaged within a lighted walk-in equipment enclosure with a main access door.

The design of the chiller is matched specifically for the operating environment for which it is to be installed. The complete packaged chiller will be set in place, piped, and electrically connected.


Electrical

Compressor Module Electrical Enclosure
A NEMA rated central electrical enclosure & PLC screen are usual requests for larger chiller applications. However, each compressor section can have its own self contained operating and safety panel mounted inside individual enclosures. This panel will include the compressor starters, bypass pump starters, suction and discharge safety controls, and condenser fan VFD (for air cooled models). The panel may be vented through a small vent opening on the bottom along with an exhaust fan. The enclosure includes hinged access with a locking “T” handle for easy access.

The process chiller is complete with single point wiring to the main tie in block. The electrical box and interior of the chiller are weatherproof by means of neoprene gaskets around all accessible openings.


Compressor Run-time Sharing
Each compressor module will utilize a relay to switch the compressors in the circuit with every off-cycle. Run-time will also be share by staging up the final compressors in reverse order. This ensures that compressors share run-time without a more complex logic control.


Fan Controls - Variable Frequency Drives (Air Cooled Models)
Each compressor section is equipped with a 4-20ma pressure transducer located on the discharge line of the compressor. This transducer is directly wired to the Condenser Fan VFD which operates the two condenser fans per compressor section. The VFD, when powered, provides power to the transducer. The scaled pressure range within the VFD senses the discharge pressure of the compressor section and modulating the fan RPM appropriately. Each fan VFD is sized to handle the combined horsepower of both fan motors at design conditions. The VFD’s are rated to operate without de-rating to 122°F. An auto reset electromechanical pressure switch will not allow fan operation below 200 PSI.

The VFD’s also provide the following protections
  • Short circuits within internal power supplies
  • Short circuits between output phases
  • Short circuits between output phases and ground
  • Input phase loss
  • Thermal protection against overheating and over-currents
  • Under-voltage and over-voltage fault
 
 
 